why does aluminum darken after machining insights from keruns laboratory tests-0

Why Does Aluminum Darken After Machining? Insights from KERUN’s Laboratory Tests |

All Categories
Why Does Aluminum Darken After Machining? Insights from KERUN’s Laboratory Tests |
Home> Blogs

Why Does Aluminum Darken After Machining? Insights from KERUN’s Laboratory Tests

Blogs 17 Sep 2026 / By

ADC12 aluminum parts may turn dull, gray, or even black after machining. A freshly mixed cutting fluid may perform well, yet surface quality can become less consistent over time—even when fluid concentration and pH remain within the specified ranges.

ScreenShot_2026-09-16_163424_558.png

What causes this change?

Following reports from customers, the KERUN Industrial Fluids Research Institute investigated three questions: what causes corrosion-related staining, how different corrosion inhibitors perform, and how changes in the fluid during use affect surface protection.

The study focused on phosphate ester structure and the ionic environment in water-based cutting fluids, linking laboratory findings to practical troubleshooting.

Look Beyond Fluid Concentration and pH

ADC12 is a widely used die-cast aluminum alloy containing alloying elements such as copper, magnesium, and zinc. Its surface condition can be sensitive to the machining environment.

In water-based cutting fluids, several factors can contribute to discoloration:

  • Alkalinity: An alkaline environment can affect the stability of the protective oxide film on aluminum.
  • Contact with dissimilar metals: Contact with steel or cast iron can create conditions for galvanic corrosion.
  • Water chemistry and ion buildup: Chloride in the water, together with calcium, magnesium, and aluminum ions that accumulate during operation, can increase the risk of pitting and staining.

Troubleshooting therefore requires a broader assessment of the corrosion inhibitor system, water quality, and operating conditions, alongside concentration and pH.

Phosphate Ester Structure Makes a Difference

Phosphate esters are commonly used to inhibit aluminum corrosion in water-based metalworking fluids. Their molecular structure influences how they adsorb onto the metal surface, form a protective film, and withstand changes in the ionic environment.

KERUN evaluated seven phosphate esters with representative molecular structures using full-immersion corrosion tests on ADC12 aluminum specimens.

Table 1. Corrosion ratings of aluminum specimens after immersion in purified-water test solutions.

表1 纯水下铝试片浸泡后腐蚀评级.webp

Some branched-chain alkyl phosphate esters formed relatively compact, hydrophobic adsorption films. After eight hours of immersion under purified-water conditions, the specimens retained a relatively good surface appearance. Straight-chain octyl phosphate ester also showed good initial film formation under these conditions.

By comparison, some alkyl polyoxyethylene ether phosphate esters formed less complete films. Their greater hydrophilicity and steric hindrance were associated with increased susceptibility to pitting and staining.

These results indicate that inhibitor selection should consider the specific molecular structure and film-forming ability, as well as the additive type and dosage.

Fresh-Fluid Performance Does Not Guarantee Long-Term Protection

Tests in purified water provide a useful baseline for initial protection, but they do not fully represent a cutting fluid in service.

During machining, makeup water can introduce calcium, magnesium, and chloride ions. Reactive aluminum chips can also contribute to the gradual accumulation of aluminum ions in the fluid. These changes can affect phosphate ester performance and the integrity of the protective film.

To investigate this effect, the researchers tested the seven phosphate esters at different calcium and magnesium hardness levels and aluminum ion concentrations.

Table 2. Corrosion ratings of aluminum specimens after immersion in standardized calcium–magnesium hard-water test solutions.

表2 标准钙镁硬水下铝试片浸泡后腐蚀评级.webp

Table 3. Corrosion ratings of aluminum specimens after immersion in test solutions containing aluminum ions.

表3 铝离子硬水下铝试片浸泡后腐蚀评级.webp

As calcium, magnesium, and aluminum ion concentrations increased, several phosphate esters showed a decline in corrosion inhibition, although the extent varied.

Some branched-chain alkyl phosphate esters were relatively more resistant to these changes and maintained good protection under certain hard-water conditions. Their performance also declined, however, as ion concentrations increased further.

Using purified water for the initial mix does not eliminate this risk. It reduces the introduction of calcium and magnesium ions but cannot prevent aluminum ions from accumulating during machining.

This helps explain why a fluid that performs well when freshly mixed may provide less consistent surface protection after extended use.

Protective Film Integrity Matters

The researchers further examined the aluminum surfaces using electrochemical impedance spectroscopy (EIS), scanning electron microscopy (SEM), and energy-dispersive X-ray spectroscopy (EDS).

The results showed that all the phosphate esters exhibited some adsorption onto the aluminum surface, but the integrity of the resulting films differed considerably.

A compact, continuous film limits direct contact between the alkaline fluid and the aluminum surface, helping reduce corrosion and staining. Gaps in the film leave localized areas exposed, where corrosion can develop into pitting, dullness, or black discoloration.

Figure 1. Nyquist plots for aluminum exposed to different phosphate ester test solutions.

imagetools0(e713a9f2ea).jpg

Figure 2. SEM images of aluminum surfaces treated with different phosphate esters: (a) NF-3; (b) MDIT; (c) PZ; (d) ASI80; (e) PA24; (f) PE169; (g) LB400.

图2  磷酸酯SEM图   a:NF-3,b:MDIT,c:PZ,d:ASI80,e:PA24,f:PE169,g:LB400.webp

Evaluating an aluminum corrosion inhibitor therefore requires more than confirming that it forms a film. The film must also remain effective as water chemistry changes and metal ions accumulate.

Applying the Findings on the Shop Floor

The study provides a practical framework for investigating aluminum discoloration:

  • Compare fresh and in-service fluids, alongside routine concentration checks.
  • Check mixing-water hardness, chloride levels, and other relevant water-quality factors.
  • Assess the buildup of calcium, magnesium, and aluminum ions in the fluid.
  • Review inhibitor structure, film-forming ability, and compatibility with the overall formulation.
  • Consider the aluminum alloy grade, equipment materials, machining process, and length of time the fluid has been in service.

Simply increasing fluid concentration or adding more corrosion inhibitor may not resolve the underlying issue. Assessing the material, formulation, water chemistry, and operating conditions together provides a stronger basis for identifying the cause and reducing surface defects and batch-to-batch variation.

640 (1).webp

For KERUN, customer feedback is the starting point for research that supports fluid selection, formulation development, and reliable performance in production. Connecting field observations with laboratory testing and application support helps turn these findings into practical improvements in machining stability and surface quality.

Why Does Aluminum Darken After Machining? Insights from KERUN’s Laboratory Tests |

Get Quote

Our representative will contact you soon.
Name
Email Address
Company Name
Message
0/1000
email goToTop